LED Lighting Upgrade:

Kungsleden, Vendevagen

Achieve 93% lower energy costs by switching to LED

 

Expected annual results compared to the previous lighting:

  1. 93% annual energy saving / £4825.07

  2. 93% annual CO2 savings / 15.5 tons

  3. 71% lower installed power

Extra benefits from our LED solution:

  1. 76 fluorescent fixtures replaced with 51 LED fixtures - 33% fewer fixtures

  2. Illuminance increased from 100 lux to 130 lux

  3. Intelligent sensors will increase savings where possible

  4. Simple remote to change settings if required

  5. Daylight white lighting improves visibility increasing health + safety


Project: To provide a higher illuminance with LED lighting

The Brief -

Kungsleden is one of Sweden’s largest listed property companies focusing on long-term ownership, active management, improving and developing commercial properties in chosen growth regions. Kungsleden has set a long term target of reducing energy consumption in their properties by 20 percent by 2020. Choosing the most energy-efficient LED lighting solution for their parking garage is a step towards the goal.

The Solution -

After visiting the parking garage and preparing an extensive lighting design, we proposed a lighting scheme that would provide a higher illuminance using less power than the existing lighting. After discussing the options with Kungsleden we agreed to use our LumiROD 414.

The LumiROD 414 is a real light machine with an energy efficiency of 145 lumens per watt. A variant with daylight 5300 Kelvin colour temperature was chosen in order to increase visibility in the garage.

The LumiROD 414 has a high degree of protection (IP66) with a smooth top side which is well suited for parking garages or other dirty areas. This means that the luminaire shines longer and brighter with less maintenance requirements.

The LumiROD 414 is fully dimmable from 0-100%. In this garage the luminaires have been fitted with a built-in combined light and motion sensor. The built-in motion sensor can be set on the lowest setting between 0-90% power. The time for how long the luminaire shall be operated at full power when motion is detected is adjustable from 0-99 minutes.

In the garage the luminaires were set to the lowest setting uses 10% power (3.6 watts). When motion is detected the lights increase to 36 watts (full power) for 10 minutes. Luminaires in the middle of the garage are set up so that they switch off completely to save even more energy. By setting the luminaires along the walls to dim to 10% when there is no motion dark corners in the garage are avoided. The motion sensor can be adjusted on site with a remote control if you later want to change the settings for further optimisation.

BOOK YOUR FREE SITE SURVEY

Previous
Previous

Kungsleden Vendevagen

Next
Next

Green Park Vanadisgaraget